Click to Sign up for a Free Newsletter read by 50,000 people across the world

NewsArticlesInterviewsPress releasesRegulatoryResourcesCompaniesProductsMaterialsMachineryEventsSearchNewsletter

Home › Article

Article

GLP-1 medicines are changing drug delivery: manufacturing challenges for pens, syringes and oral formats

Published on Pharmaceutical Weekly 27 November 2026 · 12 min read

By Priti Patel

Illustration of injection pens, prefilled syringes and a tablet with molecule models
Image credit: Illustration for Pharmaceutical Weekly · Image source

Manufacturing and quality questions for GLP-1 pens, syringes and oral tablets: combination-product CGMP, device performance, the oral SNAC excipient, peptide impurities and distribution integrity, as of 27 November 2026.

Demand for GLP-1 medicines has put attention on a part of pharma that is often out of view: how a peptide drug is made, packaged into a delivery device, filled under aseptic conditions, stored and kept authentic as it reaches the patient. This article looks at those manufacturing and quality questions for pens, prefilled syringes and oral tablets. It gives no clinical or dosing advice and does not rank products or companies.

Last reviewed: 27 November 2026. Regulatory statements come from the FDA, EMA and eCFR documents in the references. Passages marked as interpretation are the author's analysis, not regulatory text.

Three formats, three different manufacturing problems

A multi-dose pen, a single-dose prefilled syringe and a tablet all deliver the same class of active substance, but each shifts risk to a different part of the operation. A pen or syringe is a drug and a device working together. A tablet has no device, but depends on getting a peptide absorbed through the gut. Interpretation: a manufacturer entering this area should treat format choice as a quality-system decision first and a capacity decision second, because each format brings a different regulatory file, supplier base and stability programme.

Pens and syringes: combination-product quality systems

In US regulation, a drug-device product of this kind is a combination product. 21 CFR Part 4, subpart A sets its current good manufacturing practice (CGMP) requirements. Under 21 CFR 4.4, compliance is achieved through a CGMP operating system demonstrated to comply either with each applicable set of CGMP regulations for each constituent part, or with the streamlined approach in paragraph (b). For a product with drug and device parts, that route starts from drug CGMP compliance and adds specified clauses of ISO 13485, including design and development (with documented risk management) and purchasing, and certain Quality Management System Regulation provisions.

Interpretation: this is where contract manufacturers and sponsors most often need to align. Design controls usually sit with a device team, batch records with a drug quality unit, and supplier controls with both. A single owner for each constituent part's change control avoids a device change reaching the filling line without a drug-side assessment.

Device performance: glide force, injection time and silicone

FDA's draft guidance on essential drug delivery performance characteristics (EDDCs), Revision 1, October 2026, is a draft; FDA notes that guidance documents do not establish legally enforceable responsibilities. It defines an EDDC as a system-level drug delivery function that depends on the device design and is not user dependent. Its worked example is a prefilled syringe with a needle and silicone oil lubricant: break-loose and glide forces are EDDCs, while silicone quantity and needle inner diameter are component-level aspects already reflected in glide force. For an autoinjector, injection time is an EDDC, and break-loose and glide forces are lower-level aspects reflected in it. Injection depth is not an EDDC in the example because it depends on the user.

FDA's 2013 guidance on pen, jet and related injectors lists design features to describe in a submission, including dose, dose accuracy, rate of injection, compatible needles and the human factors needed for safe and effective use.

Interpretation: the practical lesson is to control the characteristic that matters to delivery, not only its component inputs. A line that tightly controls silicone quantity but never measures glide force on finished units is controlling the cause without confirming the effect.

Human factors

FDA's guidance on applying human factors and usability engineering to medical devices says its aim is to maximise the likelihood that new devices will be safe and effective for the intended users, uses and use environments, by helping manufacturers minimise use errors and resulting harm. For a self-injection pen, that points to usability work with representative users as part of design and development.

Container closure systems and integrity

FDA's August 2026 draft guidance on container closure systems for human drugs and biological products addresses container closure systems that are also device constituent parts of combination products, and covers considerations for extractables and leachables evaluations and the associated toxicological risk assessments. For a pen or syringe, the closure system is part of the product, so materials and their compatibility with the formulation belong in development from the start.

On integrity, FDA's February 2008 guidance explains why container and closure integrity testing can replace sterility testing in the stability protocol for sterile products. Sterility tests detect only viable organisms present at the time of the test, can give false positives from contamination at the time of testing, and destroy the sample. The guidance lists properly validated physical or chemical methods (bubble tests, pressure or vacuum decay, trace gas permeation or leak tests, dye penetration, seal force, electrical conductivity and capacitance) and microbiological methods (microbial challenge or immersion) as alternatives. It states that integrity testing does not replace sterility testing for release, that a method is adequately validated if proven capable of detecting a breach, and that an appropriate integrity test should be conducted annually and at expiration, or as otherwise required. It recommends including integrity tests in the stability protocol of new marketing applications for sterile products.

Aseptic filling

Filling a sterile injectable is subject to the sterile manufacturing rules of each market. Our article on EU GMP Annex 1 covers the contamination control strategy, barrier technology and aseptic process simulation expectations.

High-volume packing: serialization, inspection and changeovers

For the US market, FDA's September 2023 guidance on the Drug Supply Chain Security Act says the enhanced distribution security requirements under section 582(g)(1) took effect on 27 November 2023, with only electronic tracing and verification at the package level unless a waiver, exception or exemption applies. A manufacturer or repackager can request an exception where a package is too small to carry the required label information. The guidance recommends GS1's EPCIS standard for exchanging transaction information, and its "should" is a recommendation, with the statute and regulations carrying the binding requirements. A pen carton at GLP-1 volumes is a serialized package in this sense, so the packing line has to print, verify and record a code for every carton.

Interpretation: at high volume, capacity is set by the slowest step in the chain from filling to pack-out, which for a pen can be assembly, inspection or serialized packing and not the filler. Three points follow for a buyer or a contract manufacturer. First, a changeover between strengths or pack presentations needs the line clearance, label reconciliation and code setup to be proven before output is quoted. Second, a rejected pen or carton has to be removed and its serialized code handled in the system so that records match physical stock. Third, capacity figures should be stated per presentation and per changeover frequency, not as one number for the line.

Oral GLP-1: a different manufacturing problem

EMA's human medicines committee recommended the first oral GLP-1 treatment, Rybelsus (semaglutide), on 31 January 2020. FDA approved Rybelsus tablets under NDA 213051 (application received 20 March 2019). FDA's cross-discipline review of that application shows what the oral format changed on the manufacturing side:

  • Each tablet is formulated with 300 mg of salcaprozate sodium (SNAC), a novel excipient that enhances absorption by transiently increasing transcellular permeability of the gastric epithelium. The other excipients named are microcrystalline cellulose, povidone and magnesium stearate.
  • Because SNAC had not been used in an approved product, the nonclinical programme assessed the excipient itself, and the review recommends a postmarketing milk-only lactation study of semaglutide and SNAC.
  • The drug product is light sensitive and is stored in blister packaging. The review recommends a 24-month expiry at 20 to 25 degrees C in blisters, based on long-term (25 C/60% RH) and accelerated (40 C/75% RH) stability data.

Interpretation: an oral peptide shifts the difficulty from sterile filling and device assembly to excipient supply, absorption-enhancer qualification and moisture and light protection. A novel excipient brings its own manufacturing and specification package, and a single-source excipient is a supply-chain dependency worth mapping early. These are details of one product's 2019 review, not rules for all oral peptides.

Peptide active substance and impurities

FDA's generic-drug presentation on synthetic peptides states that different manufacturing processes can result in different impurities, including peptide-related ones such as deletions and duplications, and that an applicant should demonstrate that differences in impurities do not raise the product's risk. In that material, for specified impurities common to the proposed generic and the reference product the level in the generic should not exceed the reference level, a new impurity above 0.5% is not acceptable, and new impurities between 0.10% and 0.5% should be identified, characterised and justified. These thresholds come from the generic (ANDA) programme and do not apply to an original application, but they show how FDA reads peptide impurity profiles.

Cold chain: what the label sets

Storage conditions come from the approved labelling, and they differ by format. In FDA's Ozempic prescribing information (revised May 2026), the multi-dose pen is stored refrigerated at 2 to 8 degrees C before first use and must not be frozen, and after first use it can be kept for 56 days at 15 to 30 degrees C or refrigerated. The single-dose prefilled syringe is stored refrigerated at 2 to 8 degrees C, and if needed can be kept at 8 to 30 degrees C for up to 28 days; it must be protected from light and kept in its carton until use.

Interpretation: two storage regimes in one product (before and after first use, or refrigerated with a limited warm allowance) mean lane qualification and excursion decisions have to be written against the label, with stability data behind each allowance.

Counterfeits and distribution integrity

FDA's 5 December 2025 alert on counterfeit Ozempic (semaglutide) is a documented example of why distribution integrity matters. FDA reported seizing dozens of units of counterfeit Ozempic 1 mg injection distributed outside the manufacturer's authorised supply chain but found in the legitimate US drug supply chain. The counterfeit pens carried a lot number that is also an authentic lot number, and could be told apart by the position of the EXP/LOT text on the label. FDA advised retail pharmacies to buy only through the manufacturer's authorised distributors, and patients to obtain the product with a valid prescription through state-licensed pharmacies.

FDA describes the Drug Supply Chain Security Act (DSCSA) as outlining steps to achieve an interoperable, electronic way to identify and trace certain prescription drugs at the package level as they move through the US supply chain, to prevent and detect harmful drugs and enable rapid response. FDA's 1 April 2026 notice to compounders, issued as national GLP-1 supply began to stabilise, reminds them of the conditions for the section 503A and 503B exemptions.

Interpretation: a repeated authentic lot number on a counterfeit shows that lot checks alone are weak. Label-feature checks, authorised-distributor purchasing and package-level tracing work together.

Supply, demand and compounding: what FDA's April 2026 statement says

Capacity is not only a plant question. Compounding of GLP-1 medicines is another route to patients, and FDA's 1 April 2026 statement, headed "FDA clarifies policies for compounders as national GLP-1 supply begins to stabilize", restates the conditions for them. Under section 503A, a drug must be compounded for an individual patient on receipt of a prescription, and the compounder must not regularly or in inordinate amounts compound drugs that are essentially copies of a commercially available product. FDA says it generally treats a product with the same active ingredient in the same, similar or easily substitutable strength and the same route as essentially a copy, unless a prescriber documents a significant difference for an identified patient. Its stated example is a compounded product that combines semaglutide with vitamin B12 within 10% of the commercial strengths. FDA says it does not intend, at this time, to act against a compounder that fills four or fewer prescriptions of such a product in a calendar month.

Under section 503B, outsourcing facilities may not compound from bulk drug substances unless the substance is on the 503B bulks list or the drug is on FDA's shortage list at the time of compounding, distribution and dispensing. FDA states that tirzepatide and semaglutide do not currently appear on either list.

Interpretation: for a contract manufacturer the planning point is that demand can move with supply status and policy, so a capacity case built on a shortage period should state what happens to volume when supply stabilises. This article does not cover pricing or affordability, because none of the sources above sets out price data, and it gives no clinical advice.

Illustrative scenario

This is a made-up example, not a named company. A contract manufacturer is asked to take on a prefilled-pen programme. Before quoting capacity, it maps which constituent part each quality procedure belongs to, decides which route under 21 CFR 4.4 it will follow, identifies the delivery performance characteristic it will test on finished units, and asks the sponsor for the usability report, the container closure compatibility data and the storage allowances the label will carry.

Questions to ask before taking on a line (interpretation)

  • Which CGMP route under 21 CFR 4.4 applies, and who owns change control for each constituent part?
  • Which system-level delivery characteristic (for example glide force) is measured on finished units?
  • What extractables and leachables and integrity evidence exists for the closure system?
  • For an oral product, how is any novel absorption enhancer sourced and specified?
  • Are cold-chain excursion rules written against the label's storage allowances?
  • How are suppliers and distributors verified as authorised?

Related reading on Pharmaceutical Weekly: regulatory updates, machinery and resources.

References

  • eCFR, 21 CFR 4.4, How can I comply with these current good manufacturing practice requirements for a co-packaged or single-entity combination product: ecfr.gov
  • FDA draft guidance, Container Closure Systems for Human Drugs and Biological Products (August 2026): fda.gov
  • FDA, Applying Human Factors and Usability Engineering to Medical Devices: fda.gov
  • FDA, counterfeit Ozempic (semaglutide) alert, 5 December 2025: fda.gov
  • FDA, policies for compounders as national GLP-1 supply begins to stabilize, 1 April 2026: fda.gov
  • FDA, Essential Drug Delivery Performance Characteristics for Devices Intended to Deliver Drugs and Biological Products, draft guidance Revision 1 (October 2026): fda.gov
  • FDA, Technical Considerations for Pen, Jet, and Related Injectors Intended for Use with Drugs and Biological Products (June 2013): fda.gov
  • FDA, Rybelsus (semaglutide) tablets, NDA 213051 approval letter and Cross Discipline Team Leader Review (2019): approval letter, review
  • EMA, First oral GLP-1 treatment for type 2 diabetes, 31 January 2020: ema.europa.eu
  • FDA, Assessing Immunogenicity Risk of Peptides: the Synthetic Peptide Guidance and PSGs (SBIA 2022 presentation): fda.gov
  • FDA, Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products (February 2008): fda.gov
  • FDA, Drug Supply Chain Security Act (DSCSA): fda.gov
  • FDA, Ozempic (semaglutide) injection prescribing information, revised 05/2026, section 16: accessdata.fda.gov
  • US FDA, Drug Supply Chain Security Act Implementation: Enhanced Drug Distribution Security Requirements Under Section 582(g)(1) of the FD&C Act, guidance for industry (September 2023): fda.gov

Pharmaceutical Weekly newsletter

One email each month: new products, regulatory updates and a featured article.