Pharmaceutical water systems: preventing biofilm, endotoxin and microbial excursions
What WHO TRS 1033, the EMA inspectors' Q&A on non-distillation WFI and biofilms, and the FDA high purity water inspection guide say about grades, loop design, monitoring, limits and maintenance, as of 27 November 2026.
A water system is the largest utility most drug plants run, and the one where a problem can sit unseen for days. Water reaches almost every product, cleaning step and piece of equipment, so a microbial excursion rarely stays local. This article follows the three documents most often used to frame the discussion: the WHO guidance on water for pharmaceutical use (TRS 1033, Annex 3, 2021), the EMA inspectors' questions and answers on water for injections made by non-distillation methods and on biofilms (EMA/INS/GMP/443117/2017), and the US FDA's 1993 inspection guide for high purity water systems.
Last reviewed: 27 November 2026. The FDA guide is an older inspection guide, not current regulation, and the WHO and EMA texts are guidance. Passages marked as interpretation are the author's analysis.
Grades of water and where each belongs
WHO describes three grades of water for pharmaceutical use: drinking-water, bulk purified water (BPW) and bulk water for injections (BWFI). Drinking-water is the minimum-quality feedwater for both BPW and BWFI in the WHO text. BPW is prepared by a qualified purification technique or sequence, for example ion exchange, reverse osmosis (RO), RO with electro-deionisation, ultrafiltration or a combination. BWFI is the highest-quality pharmacopoeial grade and is an intermediate bulk product used as an ingredient in formulation, not a final dosage form. WHO says it should be used, for example, for dissolving or diluting substances during manufacture of injectable products. WHO leaves the exact specification to the pharmacopoeia chosen under the marketing authorisation. The WHO annex does not define a separate highly purified water grade, so a site that uses one should write its specification and use from its own pharmacopoeia and licence.
The FDA guide makes the same link between product and grade: parenteral products, where pyrogens are a concern, are expected to use Water for Injection, while topical and oral products need less pure water and the guide notes that endotoxin limits do not apply to them in the same way.
Generation: distillation, membranes and what the EMA text adds
WHO says BWFI may be prepared by distillation as the final step, or by other means, naming deionisation, electro-deionisation, nanofiltration, ultrafiltration, softening, descaling, pre-filtration, degasification and ultraviolet treatment in conjunction with single- or double-pass RO. The European Pharmacopoeia WFI monograph, as quoted in the EMA document, permits distillation or a purification process equivalent to distillation, with RO coupled to suitable techniques such as electro-deionisation, ultrafiltration or nanofiltration, and requires notice to the supervisory authority before implementation. The EMA Q&A states that the process should be proven equivalent to or better than distillation.
The EMA text is direct about why this matters: RO systems typically run at ambient temperature and so offer an environment for biofilm, and biofilms protect their organisms against shear and disinfectants, so incomplete removal leads to rapid regrowth. Its design points for a membrane-based WFI system include pre-treatment to remove organics, control scaling and fouling, and remove chlorine (which damages membranes), with monitoring of oxidising agents upstream of the RO using, for example, oxidation-reduction potential electrodes. Suitable materials include 316L stainless steel, PVDF and polypropylene, and storage and distribution should permit routine thermal (pure steam or hot water) and/or chemical sanitisation.
Interpretation: the choice between distillation and a membrane train is a risk and control-strategy choice, not only a cost choice. The FDA guide makes a related point for hot systems: hot (65 to 80 °C) systems are self-sanitising, and the cost of maintenance, testing and problems in a cooler system may exceed the energy saved. A membrane train can be qualified, but it asks the site to prove more with monitoring, sanitisation and maintenance data.
Storage and distribution: loops, dead legs, flow and temperature
WHO says distribution should be designed as a loop with continuous circulation of BPW and BWFI, or that a one-way system be justified with robust monitoring. It lists controls to consider: continuous circulation with turbulent flow, evidenced for example by a Reynolds number above 4000; hygienic design with zero dead-leg diaphragm valves where possible and dead legs measured and calculated; pipework installed for full drainage, with a guidance slope of not less than 1/100; UV lamps with independent monitoring where needed; and operation at elevated temperature, for example above 70 °C, if required. WHO notes that systems kept at elevated temperature are generally less susceptible to microbial contamination and that lower-temperature systems need special precautions. For storage vessels it lists drainable design, prevention of stagnant water in the headspace with spray balls or distributors, integrity-tested hydrophobic bacteria-retentive vent filters, and double tube-sheet heat exchangers where used. It also says filtration should not be used in distribution loops or at take-off user points.
The FDA guide gives the older inspection view of dead legs: a design rule of an unused portion no longer than six pipe diameters was developed for hot circulating systems at 75 to 80 °C, while for cooler systems any drop or unused length can form biofilm. It calls for no threaded fittings, with sanitary fittings or butt welds, and says ball valves are not sanitary because the centre can hold water when closed. It also notes that point-of-use 0.2 micron filters can mask contamination in the system and that a filter's purpose and change frequency should be defined from validation data.
Biofilm and endotoxin
The EMA Q&A describes biofilm formation as attachment, colonisation, growth and detachment, with organisms secreting extracellular polymeric substances that anchor them to surfaces. Its central point for monitoring is that biofilm is usually unknown until an out-of-specification result appears, because detached material makes contamination sporadic and a grab sample may miss it. It adds that there are no specific European Pharmacopoeia tests for some of the by-products, such as exotoxins and bacteriocins, although several endotoxin tests exist. Its control strategy list runs from feed water design, turbulent flow, no dead legs, drainage, materials and surface roughness, welds and air filters to cleaning and sanitisation, qualification, training, preventive maintenance, utilities, deviation handling, root cause analysis and CAPA.
The FDA guide adds that for WFI the concern is endotoxin. It states that WFI can pass the LAL endotoxin test and still fail the microbial action limit, so both should be monitored, and that the microbiological test, run on a much larger sample volume than the endotoxin test (100 mL against 0.1 mL in the guide's example), is a useful index of contamination. It also warns that contamination is not evenly distributed, because attached organisms are shed continuously, so a sample may not be representative.
Monitoring, sampling and trending
WHO expects continuous monitoring through a combination of online and offline instruments linked to qualified alarms: flow, pressure and temperature online, plus conductivity and TOC where possible, with periodic offline testing to confirm online readings. Samples should be taken from points of use and dedicated sampling points with the same method as in production, and results should be analysed statistically at defined intervals (the text gives monthly, quarterly and annually as examples) with control limits such as 3 sigma. Alert and action levels are set from historical data, and adverse trends and out-of-limit results are investigated for root cause with corrective and preventive action. Where BWFI is contaminated with microorganisms, WHO says the organism should be identified.
The EMA Q&A suggests sampling every critical point during initial qualification, including feed water, pre-treatment stages, before and after the RO membrane, after final purification, the storage tank, all user points and the loop return, with daily testing for a defined period and then a longer phase covering seasonal variation. For routine operation it expects daily sampling of all user points used that day and the return loop. It encourages rapid methods, including rapid endotoxin testing and alternative quantitative microbiological methods under Ph. Eur. 5.1.6, alongside conductivity and TOC. It states that alert levels should be reassessed to tighten limits where possible and that raising limits is not good practice and may mask a failing system, and that trend review should look at raw quantitative and identification data, not only percentages of alerts and actions.
The FDA guide treats limits differently from a pass or fail view: it says none of the limits for water are pass/fail limits, all are action limits, and when exceeded the firm must investigate, correct and assess the impact on product made with the water. Its example action limit for WFI of less than 10 CFU per 100 mL is stated as agency policy in that 1993 guide; the WHO and EMA texts reviewed here do not give a number, and a site's limit should come from its pharmacopoeia, licence and trend data.
Qualification, maintenance and review
WHO describes a three-phase approach: at least two weeks of intensive testing with the water not used for product, a further two weeks during which product use may be acceptable if QA approves, and a third phase so that all three cover at least twelve months across seasons, with data trended and a review after phase 3. The FDA guide describes the same three-phase logic. WHO's maintenance programme list includes defined frequencies for filters and instruments, a calibration programme, SOPs, spare parts control, preventive maintenance with cleaning afterwards, review and approval before return to use, and records of faults. The EMA text adds routine regeneration of pre-treatment, resin replacement, filter, gasket, seal and membrane change-out at defined frequency or after adverse indicators, thermal or chemical sanitisation, and inspection for leaks and for biofilm risk. WHO expects a documented periodic review, for example annually, by a cross-functional team looking at changes, trends, failures, alarm history, investigations, alert and action limits, maintenance and calibration history, and the SCADA system including audit trail and user access.
Interpretation: the three sources agree on the pattern even where they differ on detail. Design out stagnation, keep the water moving, sanitise on a proven schedule, sample where contamination would show first, trend the raw data, and treat any loosening of limits as a risk in itself.
Illustrative scenario
This is a made-up example, not a named company. A site runs a double-pass RO and electro-deionisation train feeding an ambient storage and distribution loop. Its conductivity and TOC alarms are quiet, but the quarterly review shows identifications of the same Gram-negative organism at two user points. The team treats this as a trend, not an isolated result: it checks the return-loop and pre-RO samples, inspects gaskets and a rarely used branch, reviews its sanitisation records and decides whether the sanitisation frequency or sampling plan needs to change before limits are touched.
Routine review checklist (interpretation, built from the sources above)
- Is each use point matched to the right water grade and specification?
- Are loop flow, temperature and any dead-leg measurements within the qualified range?
- Have sanitisation records, and removal of any chemical agent, been checked?
- Do online conductivity, TOC and temperature readings agree with offline tests?
- Have trends and organism identifications been reviewed, not only counts?
- Were any alert or action limits changed, and why?
- Is preventive maintenance, including filters, membranes, gaskets and vent filters, up to date?
- Has the annual system review covered SCADA access and audit trail?