Nitrosamine impurities: lifecycle risk assessment, root-cause investigation and control strategy
What FDA's Revision 2 nitrosamine guidance and EMA's Article 5(3) Q&A (Rev. 24) say about sources, risk assessment, confirmatory testing, limits and lifecycle control, as of 27 November 2026.
Nitrosamine findings changed how manufacturers think about impurities. The question is no longer only what a route of synthesis intends to make, but what the plant, its reagents, its suppliers, its packaging and its storage conditions might make by accident. This article uses two current regulatory texts: the US FDA guidance Control of Nitrosamine Impurities in Human Drugs (Revision 2, September 2024) and the EMA questions and answers for marketing authorisation holders on the Article 5(3) nitrosamine referral (EMA/409815/2020, Rev. 24, 3 November 2026).
Last reviewed: 27 November 2026. Both texts are updated from time to time, and FDA keeps recommended acceptable intake values on a separate web page, so check the current versions before acting. Passages marked as interpretation are the author's analysis.
What nitrosamines are and why some are treated as mutagenic impurities
FDA describes nitrosamines as compounds with a nitroso group bonded to an amine. They can form when secondary, tertiary or quaternary amines meet nitrite salts under acidic conditions, and a second route is the oxidation of 1,1-disubstituted hydrazines. FDA states that nitrosamines are potent genotoxic agents in several animal species and that some are classified as probable or possible human carcinogens. ICH M7(R2) calls them part of the cohort of concern and recommends controlling known mutagenic carcinogens at a level where human cancer risk is negligible. An acceptable intake (AI) under M7 approximates one additional cancer case in 100,000 people on a conservative lifetime daily exposure assumption. The default threshold of toxicological concern of 1.5 micrograms per day does not apply to the cohort of concern, because these compounds can carry significant risk below it.
FDA separates two structural classes. Small-molecule nitrosamines, such as NDMA and NDEA, do not resemble the API and turn up in many products. Nitrosamine drug substance-related impurities (NDSRIs) carry the API or an API fragment and are generally unique to each API. NDSRIs form by nitrosation of the API when nitrosating compounds, such as nitrite impurities in excipients, are present.
Where they come from: a source map
FDA's guidance lists root causes that a risk assessment should walk through:
- Process conditions. Nitrites in the presence of amines under acidic conditions, including quenching residual azide with nitrous acid. Nitrite used in one step can carry over into later steps despite purification.
- Amines in reagents and solvents. Amine reagents and catalysts can contain secondary amine impurities (the guidance gives triethylamine and tetrabutylammonium bromide as examples), and amide solvents can degrade.
- Vendor-sourced materials. FDA reports nitrosamines in fresh solvents carried over during transfer between storage vessels, nitrite in some starting materials, and cross-contamination at suppliers.
- Recovered materials. Commingled recovered solvents, outsourced recovery with limited information on contents, and inadequate cleaning between customers.
- Process equipment and conditions. Forced-air steps such as fluid bed drying at elevated temperature and jet milling can create conditions for formation in at-risk APIs.
- Finished product. Nitrite is common in excipients at ppm levels and varies by lot and supplier, nitrite and nitrosamines may be in potable water, and some container closure systems, secondary packaging and equipment can contribute. NDSRI levels may increase during storage.
The EMA Q&A adds, for biological products, three aspects that raise risk: chemically synthesised fragments, processes in which nitrosating reagents are added deliberately, and primary packaging such as blister packs containing nitrocellulose.
Risk assessment across API, excipient and finished product
Both agencies point to ICH Q9 quality risk management. FDA recommends prioritising at-risk APIs and products by maximum daily dose, duration of treatment, therapeutic indication and number of patients treated. EMA says marketing authorisation holders, with API and finished product manufacturers and raw material suppliers, are required to perform risk evaluations, that suppliers should give the holder all information needed, and that development-stage assessments can support the evaluation. FDA's three-step strategy is to assess risk, perform confirmatory testing if a risk is identified, and report changes. EMA asks holders to tell competent authorities of the outcome of the risk evaluation even when no risk was identified.
FDA also notes a point that matters for planning: routine HPLC tests for purity, identity and known impurities are unlikely to detect nitrosamines, and different failure modes can give different nitrosamines in different batches from the same process.
Interpretation: a risk assessment that stops at the synthetic route misses most of the list above. The useful version is a map of every material, solvent, recovery loop, excipient, water source, packaging component and storage condition that touches the product, with the supplier named for each.
Confirmatory testing, method sensitivity and reference standards
EMA says confirmatory testing should generally be done on the finished product, with testing of the API, intermediates, starting materials, solvents, reagents or excipients also recommended where the risk assessment points there; if the control point is not the finished product, the holder remains responsible for quality. Batch numbers should be commensurate with risk. Where the source of risk is well understood, for example by spike and purge studies, EMA's text says testing 10% of annual batches or three per year, whichever is higher, and all batches if fewer than three are made, including retained samples still within expiry. Strengths of the same dosage form with the same risk factors can be tested by worst case. A reference standard is generally needed for method development, and if despite extensive efforts it cannot be synthesised, EMA says this could indicate the nitrosamine does not exist or is not formed, with thorough justification case by case.
On sensitivity, EMA states that the limit of quantification should be at or below the acceptable limit for routine control, at or below 30% of it to justify skip testing, and at or below 10% to justify omitting a specification, with exceptions for high daily doses or multiple nitrosamines. Where more than one method or analyte is used, selectivity should be shown for each nitrosamine.
Limits without a universal number
Neither text gives one limit for every substance. FDA recommends using its published recommended AI limits, or the Carcinogenic Potency Categorization Approach where robust data are lacking, and a scientifically justified different AI is allowed. Where an AI cannot be determined by those approaches FDA recommends 26.5 ng/day as the AI. To turn an AI into a ppm control limit, FDA gives the calculation: ppm equals AI in ng/day divided by maximum daily dose in mg, so the same AI gives different ppm limits for different products. For several nitrosamines, FDA says the total should not exceed the AI of the most potent one, and offers an alternative flexible approach in an appendix; EMA's text uses a total risk below 1 in 100,000. Products for advanced cancer fall under ICH Q3A/Q3B in FDA's text. Because both documents say these values are updated, any limit used in a specification should be checked against the current agency page for that substance.
Root cause and what to do after a detection
EMA says that when a nitrosamine is detected for the first time the holder should inform competent authorities forthwith, whatever the amount, report levels in ng and ppm with exposure calculations at the maximum daily dose, and compare them to the applicable limit. If the limit is met, the holder controls at or below it and mitigates as far as possible. If it is exceeded, the holder should submit an interim investigation report with preliminary root cause, mitigation plan and benefit/risk assessment. For mitigation EMA lists process change, raw-material quality change, specifications and methods, and measures on premises and equipment such as cleaning and environmental monitoring. FDA's root-cause list above gives the investigation its structure: precursor amine, nitrosating agent, conditions, carryover and supply chain.
After the test: confirmatory testing, API changes and reporting under FDA's guidance
The FDA guidance describes a three-step strategy: assess the risk, run confirmatory testing where there is any risk, and report the changes made to prevent or reduce nitrosamines. Risk assessments do not have to be submitted but should be kept so they can be produced on request, and they should be revisited periodically, including for nitrosamine drug substance-related impurities (NDSRIs) if an earlier assessment left them out. The guidance says the test methods need specificity, excellent chromatographic separation and highly sensitive detection, because nitrosamines have low molecular weights, some volatility and high toxicity.
For a drug product judged at risk, confirmatory testing should generally be done. The guidance offers one exception to routine testing: where formation could happen through nitrosation of the API or its fragments, a company may show in its risk assessment, by subjecting the drug to nitrosating conditions in targeted forced degradation, that no nitrosamine forms, and that data-driven justification may support omitting confirmatory testing. Without it, testing should be done, and it should cover at least three representative batches.
API manufacturers are asked to review their processes and test batches with sensitive, validated methods when a risk is found. If a nitrosamine is detected they should investigate the root cause and change the process to prevent formation. The agency encourages API manufacturers to use the field alert reporting system if early testing shows nitrosamine formation in an API already sold for the US market, and to tell the drug product manufacturers they supplied so that a recall decision and shortage risk can be considered.
On reporting, a drug master file holder that changes the route of synthesis as a result must submit an amendment and inform each drug product manufacturer or applicant that references the file. If the old process cannot be stopped at once, both processes may be described in the file with separate codes to identify batches, with an estimated date to remove the original. Reworked or reprocessed API batches should be reported in the file or application. For finished products, the guidance notes that adding antioxidants or pH modifiers has been shown effective by FDA laboratories and can be a reformulation route, which is itself a change that must be reported under the applicable regulations.
Change control and lifecycle monitoring
EMA says changes should go in through timely variations, with new specifications reflecting the limits, and that holders should control nitrosamine levels against any change that may affect risk, such as a change of supplier, process or packaging. FDA states manufacturers should take measures to prevent unacceptable levels throughout the product life cycle and that changes to approved applications should be reported under its change regulations.
Interpretation: the lifecycle point is that a clean result is a snapshot. A new excipient supplier with higher nitrite, a switch to a recovered solvent or a new blister material can reopen a closed assessment, so the assessment should be tied to change control with named triggers.
A hypothetical investigation flow
This is a made-up example, not a named product. A tablet containing an API with a secondary amine shows a low-level NDSRI in a stability study. The team first confirms the identity with a reference standard and checks that the method's LoQ is below the applicable limit. It converts the limit to ppm using the labelled maximum daily dose and compares the result. It then asks, in order: is the NDSRI in the API or does it grow in the tablet; do excipient lots carry measurable nitrite; has the water, equipment or packaging changed; and does the level rise during storage? Depending on the answers it may tighten the excipient nitrite specification, change packaging, adjust the process or reformulate, and it reports according to the regulator's rules.
Related reading on Pharmaceutical Weekly: regulatory updates and resources.