Click to Sign up for a Free Newsletter read by 50,000 people across the world

NewsArticlesInterviewsPress releasesRegulatoryResourcesCompaniesProductsMaterialsMachineryEventsSearchNewsletter

Home › Article

Article

Antibody-drug conjugates: the manufacturing and containment challenge behind targeted oncology

Published on Pharmaceutical Weekly 27 November 2026 · 7 min read

By Lisa Kremer

Illustration of an antibody with drug payloads inside a containment glovebox
Image credit: Illustration for Pharmaceutical Weekly · Image source

How ADC architecture, conjugation quality attributes and potent-payload containment shape manufacturing, using FDA's review of one approved ADC and EU guidance, as of 27 November 2026.

An antibody-drug conjugate (ADC) joins a targeting antibody to a cytotoxic payload through a chemical linker. The idea is to deliver the payload to cancer cells while limiting exposure elsewhere. For manufacturers, the same design creates a double problem: a large-molecule biologic that must be made and controlled like an antibody, and a highly potent small-molecule payload that must be handled in a way that protects both operators and other products. This article uses one FDA review and EU guidance texts to show how those two problems meet.

Last reviewed: 27 November 2026. The product example is one FDA chemistry review from 2019 and is not a rule for every ADC. Passages marked as interpretation are the author's analysis, not regulatory text.

Architecture: antibody, linker and payload

FDA's chemistry review of POLIVY (polatuzumab vedotin), BLA 761121, describes a CD79b-targeted ADC that delivers the anti-mitotic agent monomethyl auristatin E (MMAE) to B cells. The molecule consists of MMAE covalently attached to a humanised IgG1 monoclonal antibody, produced in CHO cells, through a protease-cleavable linker (mc-vc-PAB). The manufacturing process was designed to deliver an average of 3.5 linked MMAE moieties per antibody, a drug-to-antibody ratio (DAR) of 3.5. The finished product is a sterile, preservative-free lyophilised powder in single-dose vials for intravenous infusion after reconstitution and dilution.

Each of the three parts has its own quality questions. The antibody is a monoclonal antibody process. The linker-payload (the review calls it the drug-linker intermediate, vcMMAE) is a chemical synthesis, and in this application its manufacture and stability were described in a drug master file, with limits on conjugatable impurities, residual solvents and residual palladium reviewed there. The conjugation step joins the two.

The process sequence

The review describes the antibody intermediate being conjugated with the drug-linker intermediate to make the drug substance, which is then formulated and filled as a lyophilised product. Interpretation: that sequence puts three regulated steps in a chain: biologic production, potent-compound synthesis and sterile lyophilised fill. A delay or deviation in any of them affects the others, and the drug-linker intermediate's hold time becomes a scheduling constraint. The review itself lists data supporting control of vcMMAE stability, including hold times.

Critical quality attributes that come from conjugation

In the review's table of critical quality attributes, the conjugation-related ones include the drug-to-antibody ratio, the percentage of unconjugated antibody, drug distribution and off-target conjugation, meaning conjugation of the drug-linker to the antibody at locations other than the intended sites. The review ties these to potential impact on pharmacokinetics and bioactivity and to the drug substance conjugation process as their origin. Two potency methods relevant to the mechanism of action are in the commercial control strategy: a binding ELISA that measures the ability of conjugated antibody to bind CD79b, and a cell-based bioassay that measures killing of CD79b-positive cells. A two-tier reference standard system, with primary and secondary standards and a requalification protocol, was set up for commercial use.

Interpretation: a biologic specification is built around the antibody. An ADC specification adds attributes that exist only because of the conjugation chemistry, so the analytical package has to measure the average ratio and also how the payload is distributed.

Conjugation chemistry and size variants

The chemistry fixes which attributes need watching. In the review, the drug-linker (a maleimidocaproyl-valine-citrulline linker with a self-immolative spacer, carrying MMAE) is bound to the reduced interchain cysteine residues of the antibody heavy and light chains through a thioether bond. Interpretation: because the attachment sites are the interchain cysteines, the number of payloads per antibody, their distribution and any conjugation at unintended sites depend on how far those cysteines are reduced and how the conjugation step is run. The review lists the unconjugated antibody fraction, drug distribution and off-target conjugation among its conjugation-related attributes.

The review's attribute table also lists size-related variants, with high-molecular-weight and low-molecular-weight forms, as a product-related attribute with potential effects on bioactivity, pharmacokinetics, immunogenicity and safety, and names the manufacturing process and storage as origins. Aggregates therefore matter for an ADC for the same reasons as for the naked antibody, and they are tied to storage as well as to the process. The public version of the review redacts the analytical methods behind these attributes, and payload synthesis sits in a drug master file, so neither is described here.

Quality by design and batch consistency

The review describes a risk-based approach to the antibody intermediate formulation using a multi-parameter design of experiments, development studies, stability studies and a risk ranking and filtering assessment. Conjugation parameter ranges were based on that risk ranking and prior knowledge, control capability of the manufacturing process or a scale-down process parameter validation study. Product variants and process-related impurity attributes were identified using a risk tool that evaluates each attribute's impact on patient safety and efficacy.

Interpretation: for batch consistency the useful message is that conjugation is treated as a process with defined, justified parameter ranges, not as a step to be fixed after the fact. Scale-down models matter here, because running conjugation experiments at full scale means handling potent material at large volumes.

Containment and cross-contamination

Two different rule sets apply to a potent payload, and they answer different questions.

  • Protecting other products. EU GMP Chapter 3 (point 3.6) says cross-contamination should be prevented for all products by appropriate design and operation, with measures commensurate with the risk, using quality risk management. Dedicated facilities are required where the risk cannot be adequately controlled by operational or technical measures, where toxicological evaluation does not support a controllable risk, or where residue limits derived from the toxicological evaluation cannot be satisfactorily determined by a validated analytical method. EMA's guideline on health-based exposure limits describes deriving a permitted daily exposure (PDE) from toxicological data, and says carry-over limits used in cleaning validation are widely based on such limits.
  • Protecting workers. The EU Directive 2004/37/EC covers worker exposure to carcinogens, mutagens and reprotoxic substances, and EU-OSHA notes that hazardous medicinal products which contain such substances fall within its scope. In the US, NIOSH describes occupational exposure limits and a banding process for chemicals that lack one, which assigns a chemical to one of five bands (A to E) based on toxicological potency and health effects.

Interpretation: a payload's toxicological data decides both. A low PDE drives cleaning limits and the case for dedicated or segregated equipment. A low occupational limit or high band drives enclosure, air handling and gowning. Neither answer comes from the fact that the product is an ADC. Each comes from the payload's own data.

Capacity, CDMOs and technology transfer

The FDA review notes that the drug product manufacture site was already approved for four other FDA-approved products, including two antibody drug or toxin conjugates, and recommended it as acceptable. Interpretation: prior experience with conjugates is visible to regulators when they assess a site. For a company choosing a contract partner, the practical checks are whether the site already runs conjugation under containment, whether it can run the payload's analytical methods, and who owns the drug-linker intermediate supply. Technology transfer for an ADC moves three process packages and their analytical methods, not one.

Illustrative scenario

This is a made-up example, not a named company. A biotech with an antibody programme chooses a contract partner for conjugation. It asks for the payload's toxicological summary, the partner's PDE-based cleaning limits for shared equipment, and the analytical methods for DAR and unconjugated antibody. It also writes a hold-time plan for the drug-linker intermediate before the first engineering batch.

Questions to ask before choosing a facility (interpretation)

  • Does the payload's toxicological data support shared equipment, or does it call for dedicated or segregated equipment?
  • How were cleaning limits derived, and is the analytical method validated at that limit?
  • Which occupational limit or band applies, and how do the enclosure and air handling meet it?
  • Can the site measure DAR, unconjugated antibody, drug distribution and off-target conjugation?
  • What are the hold times for the drug-linker intermediate, and who supplies it?

Related reading on Pharmaceutical Weekly: regulatory updates, machinery and resources.

References

  • FDA CDER, Chemistry Review, BLA 761121 (POLIVY, polatuzumab vedotin), 2019: accessdata.fda.gov
  • European Commission, EudraLex Volume 4, Part 1 Chapter 3: Premises and Equipment: health.ec.europa.eu
  • EMA, Guideline on setting health based exposure limits for use in risk identification in the manufacture of different medicinal products in shared facilities (EMA/CHMP/CVMP/SWP/169430/2012): ema.europa.eu
  • EU-OSHA, Directive 2004/37/EC, carcinogens, mutagens or reprotoxic substances at work: osha.europa.eu
  • CDC NIOSH, Exposure Banding (Occupational): cdc.gov

Pharmaceutical Weekly newsletter

One email each month: new products, regulatory updates and a featured article.
Subscribe